Explanation of Test method description for JIS (JIS Z 0237(2022)) / Sliontec Method
JIS/Sliontec Method - Adhesion
Test method | JIS (JIS Z 0237(2022)) | Sliontec Method |
---|---|---|
Test panel | BASUS plate | Polished SUS plate / BASUS plate |
Test specimen (width) | 24mm | 25mm |
Applying process | 10mm/sec. × 2 to-and-fro | 5mm/sec. × 1 to-and-fro |
Test procedure | Stick to the tape to the test panel by applying pressure with a roller | Crimping after pasting |
Time until measurement | Within 1 minute after applying pressure | 20 to 40 minutes after applying pressure |
Measured data | Disregard the measured value of length of first 25mm, and measure every point for the length of 50mm after that (Measure every less than 1mm) |
Measure every 20mm 4 times |
∗ We measure with 25mm, and calculate in terms of 10mm.
Adhesion - "JIS method" and "Sliontec Method"
Test panel - "BASUS plate" and "Polished SUS plate"
JIS/Sliontec Method - Holding power
Test method | JIS (JIS Z 0237(2022)) | Sliontec Method |
---|---|---|
Test panel | BASUS plate | Polished SUS plate / BASUS plate |
Test specimen (width) | 8∼25mm × 8∼25mm | 25mm × 25mm |
Applying process | 10mm/sec. × 2 to-and-fro | 5mm/sec. × 1 to-and-fro |
Time until measurement | Measure within 1 minute | After 20 to 40 minutes |
Measured temperature | 23 degrees C | 23 degrees C or 40 degrees C |