JIS/Sliontec Method - Adhesion

Test methodJIS
(JIS Z 0237(2022))
Sliontec Method
Test panel BASUS plate Polished SUS plate / BASUS plate
Test specimen (width) 24mm 25mm
Applying process 10mm/sec. × 2 to-and-fro 5mm/sec. × 1 to-and-fro
Test procedure Stick to the tape to the test panel by applying pressure with a roller Crimping after pasting
Time until measurement Within 1 minute after applying pressure 20 to 40 minutes after applying pressure
Measured data Disregard the measured value of length of first 25mm, and measure every point for the length of 50mm after that
(Measure every less than 1mm)
Measure every 20mm 4 times

∗ We measure with 25mm, and calculate in terms of 10mm.

Adhesion - "JIS method" and "Sliontec Method"

Adhesion - "JIS method" and "Sliontec Method"

Test panel - "BASUS plate" and "Polished SUS plate"

Test panel - "BASUS plate" and "Polished SUS plate"

JIS/Sliontec Method - Holding power

Test methodJIS
(JIS Z 0237(2022))
Sliontec Method
Test panel BASUS plate Polished SUS plate / BASUS plate
Test specimen (width) 8∼25mm × 8∼25mm 25mm × 25mm
Applying process 10mm/sec. × 2 to-and-fro 5mm/sec. × 1 to-and-fro
Time until measurement Measure within 1 minute After 20 to 40 minutes
Measured temperature 23 degrees C 23 degrees C or 40 degrees C

Page top